Which oil can Yateks online oil testing equipment applicable?
Suitable for lubricating oil, hydraulic oil, gearbox oil, engine oil, fuel oil, insulating oil, turbine oil, synthetic grease, various light oil, heavy oil, etc.
Oil analysis applications:
Oilfield, oil refining, wind power, hydropower, thermal power, nuclear power, power transmission and transformation, construction machinery, vehicles. Aviation, navigation, railway, road transport, steel, metallurgy, oil storage warehouses, petrol stations, industrial production lines, oil test laboratory etc.
Yateks online oil testing equipment Applicable to Manufacturing industry support: wind power, engineering machinery, automobiles, filtration equipment, military industrial support Channel Support: Distributors with integrated capabilities On-site testing kit: portable fast oil detector.
Why do we need oil condition monitoring sensors?
Due to differences in working conditions and environment, it is impossible to accurately and accurately reflect the lubrication status of equipment during operation; The period is long and the timeliness is poor; Sampling pollution risk: lubrication system pollution, sample contamination; Not conducive to building equipment health management big data cloud intelligence
Product advantages, a wide range of detection: Meet most of the oil online monitoring in the current market
Kinematic viscosity: 25~500cst;
Dynamic viscosity: 25~400cp
Density: 600 kg/m3~1300 kg/m3;
Oil pollution index range: 0‐100;
Water content range: 0~500ppm;
Temperature: -40~120 °C;
Saturation: 0~1.
Moisture content: 0-5%, 0-10%, 0-20% optional Abrasive sensor: ferromagnetic abrasive particles >50μm, non-ferromagnetic >200μm
Product application range:
Technical performance
- Pollution status evaluation
Detection channel: 8;
Flow rate range: 12 ~ 300mL / min;
On-line detection pressure: 0.2 ~ 10Mpa (optional decompression device maximum pressure up to 40Mpa);
Light source: semiconductor laser;
Particle size range: 1μm ~ 600μm;
Sensitivity: 1μm (ISO4402);
Counting volume: 10ml;
Counting accuracy: ±0.3 pollution levels.
- Lubrication status and wear evaluation
Density: 600 kg/m3~1300 kg/m3; accuracy 2%
Oil pollution index range: 0‐100; accuracy ±3%;
Water content range: 0~500ppm; accuracy ±10%;
Kinematic viscosity: 25~500cst; accuracy 5%;
Dynamic viscosity: 25~400cp; accuracy 5%;
Temperature: -40 ~ 120 ° C; accuracy of 0.3 ° C;
Saturation: 0~1. Accuracy ±10%; 0.6~0.9: ±0.03; 0.9~1: ±0.04.
Product details reference:
https://yateks.com/products/oil-analysis-instrument/
or feel free to contact us with any questions about our company and products. We love to talk with you and help you with any queries.